The underlying connection was closed: An unexpected error occurred on a receive

Came across this problem a little while ago, we had deployed a production system where we had 2 BizTalk servers which were sending messages to a large .net application.  There were 9 web servers hosting the .net web services.

Intermittently we were getting the following error message taken from the event log on the BizTalk server.

Event Type:     Warning
Event Source:   BizTalk Server 2006
Event Category: BizTalk Server 2006
Event ID:       5743
Date:           15/03/2008
Time:           13:06:02
User:           N/A
Computer:       BTSSvr1
Description:
The adapter failed to transmit message going to send port "Snd_AcmeApplicationService" with URL "wse://http://<Removed>/Acme.WebServices/CustomWebService.asmx". It will be retransmitted after the retry interval specified for this Send Port. Details:"The underlying connection was closed: An unexpected error occurred on a receive.".

Upon investigation the network guys found that 2 of the 9 web servers had been configured with the wrong Subnet Mask and when the request hit either of these boxes it was failing and the other boxes were fine.